KSh1,920,000.00

In Stock

Buy Victron Multi 3000W 70A 24V Inverter charger from Pavuta Telecoms in Nairobi, Kenya the leading Vitron authorized dealer at a very competitive price

Compare
Brand: SKU: victron-multi-3000w-70a-24v-inverter-charger Categories: , ,

Description

Victron Multi 3000W 70A 24V Inverter charger

Buy Victron Multi 3000W 70A 24V Inverter charger from Pavuta Telecoms in Nairobi, Kenya the leading Vitron authorized dealer at a very competitive price. The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features

Victron Multi 3000W 70A 24V Inverter charger  features

The MultiPlus will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.

Uninterrupted AC power (UPS function)

In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Virtually unlimited power thanks to parallel operation

Up to 6 Multis can operate in parallel to achieve higher power output. Three-phase or split phase operation is also possible. Please check our datasheets to see which models have paralleling, three phase and split phase capabilities.
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers
and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example can be connected to this output (second output available on models rated at 3 kVA
and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will provide
25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not all:
up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 2000 Amps charging
capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator or shore current can be
set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the
generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity
of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that
insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces,
the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a
DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar Chargers
can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can be
changed remotely.
MultiPlus Compact
12/2000/80
MultiPlus
24/3000/70
MultiPlus Inverter/Charger
www.victronenergy.com
MultiPlus
12 Volt
24 Volt
48 Volt
C 12/800/35
C 24/ 800/16
C 12/1200/50
C 24/1200/25
C 12/1600/70
C 24/1600/40
C 12/2000/80
C 24/2000/50
12/3000/120
24/3000/70
48/3000/35
24/5000/120
48/5000/70
PowerControl Yes Yes Yes Yes Yes Yes
PowerAssist Yes Yes Yes Yes Yes Yes
Transfer switch (A) 16 16 16 30 16 or 50 100
INVERTER
Input voltage range (V DC) 9,5 – 17 V 19 – 33 V 38 – 66 V
Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (VA) (3) 800 1200 1600 2000 3000 5000
Cont. output power at 25°C (W) 700 1000 1300 1600 2400 4000
Cont. output power at 40°C (W) 650 900 1200 1400 2200 3700
Cont. output power at 65°C (W) 400 600 800 1000 1700 3000
Peak power (W) 1600 2400 3000 4000 6000 10.000
Maximum efficiency (%) 92 / 94 93 / 94 93 / 94 93 / 94 93 / 94 / 95 94 / 95
Zero load power (W) 8 / 10 8 / 10 8 / 10 9 / 11 20 / 20 / 25 30 / 35
Zero load power in AES mode (W) 5 / 8 5 / 8 5 / 8 7 / 9 15 / 15 / 20 25 / 30
Zero load power in Search mode (W) 2 / 3 2 / 3 2 / 3 3 / 4 8 / 10 / 12 10 / 15
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1
Charge voltage ‘absorption’ (V DC) 14,4 / 28,8 / 57,6
Charge voltage ‘float’ (V DC) 13,8 / 27,6 / 55,2
Storage mode (V DC) 13,2 / 26,4 / 52,8
Charge current house battery (A) (4) 35 / 16 50 / 25 70 / 40 80 / 50 120 / 70 / 35 120 / 70
Charge current starter battery (A) 4 (12 V and 24 V models only)
Battery temperature sensor yes
GENERAL
Auxiliary output (5) n. a. n. a. n. a. n. a. Yes (16A) Yes (50A)
Programmable relay (6) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
General purpose com. port n. a. n. a. n. a. n. a. Yes Yes
Remote on-off Yes
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection battery cables of 1.5 meter M8 bolts Four M8 bolts (2 plus and 2 minus connections)
230 V AC-connection G-ST18i connector Spring-clamp Screw terminals 13
mm2 (6 AWG) M6 bolts
Weight (kg) 10 10 10 12 18 30
Dimensions (hxwxd in mm) 375x214x110 520x255x125 362x258x218 444x328x240
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1
Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles 12V and 24V models: ECE R10-4
Anti-islanding See our website
1) Can be adjusted to 60 HZ. 120 V models available on request
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general alarm,
DC under voltage or genset start/stop function
AC rating: 230 V/4A
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
Computer controlled operation and monitoring
Several interfaces are available:
Digital Multi Cont

Reviews

There are no reviews yet.

Be the first to review “Victron Multi 3000W 70A 24V Inverter charger”

Your email address will not be published. Required fields are marked *

Open chat
Need help?
Hello!
Can we help find what you need faster?