KSh425,500.00

In Stock

Eaton 9SX UPS 8 KVA RT6U

High performance Online double-conversion UPS
Performance and Efficiency
• Double-conversion topology. The Eaton 9SX constantly monitors
power conditions and regulates voltage and frequency.
• With up to 95% efficiency in online double-conversion mode
the 9SX provides the highest efficiency level in its class to
reduce energy & cooling costs.
• With a 0.9 power factor the 9SX delivers 28% more power than
UPS in its class. It powers more servers than other UPSs with
equivalent VA ratings and lower power factors.
Availability and Flexibility
• The internal bypass allows service continuity in case of internal
fault. Batteries are hot-swappable from the front panel without
powering down critical systems.
• With its tower or rack/tower versatile form factor the 9SX can be
installed in any environment (rack kit provided as standard on
RT versions).
• Stronger, longer battery life: Eaton ABM® battery management
technology uses an innovative three-stage charging technique
that extends battery life by up to 50%.
• More runtime can be added with external hot-swappable
battery modules, able to run systems for hours if necessary. The
additional battery modules are automatically recognized by the
UPS.
Manageability
• The new graphical LCD provides clear information on the
UPS’s status and measurements on a single screen (in seven
languages). LCD display position can be adjusted to offer the
best viewable angle for tower and rack usage.
• The 9SX can meter energy consumption. kWh values can be
monitored using the LCD or Eaton’s Intelligent Power
Software Suite.
• Load segment control enables prioritised shutdowns of
nonessential equipment to maximise battery runtime for
critical devices. It can also be used to remotely reboot locked-up
equipment or to manage scheduled shutdowns and sequential
start-ups.
• The 9SX offers Serial, USB and relay (dry contacts) connectivity,
plus an extra slot for an optional card (Modbus, Network or
Relay). 9SX also provides Remote Power off function. Eaton’s
Intelligent Power Software is included with each ups

Compare
SKU: eaton-9sx-ups-8-kva-rt6u Categories: , ,

Description

Eaton 9SX UPS 8 KVA RT6U

High performance Online double-conversion UPS
Performance and Efficiency
• Double-conversion topology. The Eaton 9SX constantly monitors
power conditions and regulates voltage and frequency.
• With up to 95% efficiency in online double-conversion mode
the 9SX provides the highest efficiency level in its class to
reduce energy & cooling costs.
• With a 0.9 power factor the 9SX delivers 28% more power than
UPS in its class. It powers more servers than other UPSs with
equivalent VA ratings and lower power factors.
Availability and Flexibility
• The internal bypass allows service continuity in case of internal
fault. Batteries are hot-swappable from the front panel without
powering down critical systems.
• With its tower or rack/tower versatile form factor the 9SX can be
installed in any environment (rack kit provided as standard on
RT versions).
• Stronger, longer battery life: Eaton ABM® battery management
technology uses an innovative three-stage charging technique
that extends battery life by up to 50%.
• More runtime can be added with external hot-swappable
battery modules, able to run systems for hours if necessary. The
additional battery modules are automatically recognized by the
UPS.

Eaton 9SX UPS 8 KVA RT6U  Manageability

• The new graphical LCD provides clear information on the
UPS’s status and measurements on a single screen (in seven
languages). LCD display position can be adjusted to offer the
best viewable angle for tower and rack usage.
• The 9SX can meter energy consumption. kWh values can be
monitored using the LCD or Eaton’s Intelligent Power
Software Suite.
• Load segment control enables prioritised shutdowns of
nonessential equipment to maximise battery runtime for
critical devices. It can also be used to remotely reboot locked-up
equipment or to manage scheduled shutdowns and sequential
start-ups.
• The 9SX offers Serial, USB and relay (dry contacts) connectivity,
plus an extra slot for an optional card (Modbus, Network or
Relay). 9SX also provides Remote Power off function. Eaton’s
Intelligent Power Software is included with each ups

Eaton 9SX UPS
5 kVA 6 kVA 8 kVA 11 kVA
Rating (kVA/kW) 5 kVA/4.5 kW 6 kVA/5.4 kW 8 kVA/7.2 kW 11 kVA/10 kW
Format Tower or RT (Rack/Tower) Tower or RT (Rack/Tower) RT (Rack/Tower) RT (Rack/Tower)
Electrical characteristics
Technology On-line double-conversion with Power Factor Correction (PFC) system
Nominal voltage 200/208/220/230/240 V 200/208/220/230/240 V/250 V
Input voltage range 176-276V without derating (RT models: 100-276V with derating, Tower models: 120-276V with derating)
Input frequency range 40-70 Hz, 50/60 Hz autoselection, frequency converter as standard
Efficiency Up to 94% in Online mode, 98% in Hi-Efficiency mode Up to 95% in Online mode, 98% in Hi-Efficiency mode
Crest factor/short circuit current 3:1/90 A 3:1/90 A 3:1/120 A 3:1/150 A
Overload capacity Tower models: 102-110% : 120s, 110-125%: 60s, 125-150%: 10s, >150%: 500ms
RT models: 102-130% : 120s, 130-150%: 30s, 125-150%: 10s, >150%: 100ms 102–110% : 120 s, 110–125%: 60 s, 125–150%: 10 s, >150%: 900 ms
Connections
Input Terminal block (up to 10 mm2
) Terminal block (up to 16 mm2
)
Outputs Tower models: Terminal block
RT models: : Terminal block + 2 controlled groups of 4 IEC C13 (10A) + 2 IEC C19 (16A) Terminal block
Batteries
Typical backup times at 50 and 70% load*
9SX Tower: 30/19 min RT: 13/10 min Tower: 24/15 min RT: 11/8 min 15/10 min 9/5 min
9SX + 1 EBM Tower: 120/70 min, RT: 60/40 min Tower: 90/57 min RT: 48/34 min 38/25 min 22/15 min
9SX + 4 EBM Tower : 485/275 min, RT: 220/150 min Tower: 385/220 min, RT: 170/120 min 120/82 min 80/55 min
Battery management ABM® & Temperature compensated charging method , Automatic battery test, deep discharge protection, automatic recognition of external battery units
Communication
Communication ports USB and Serial ports (cannot be used simultaneously), Dry contact, 1 Remote Power Off (all models), 1 Remote On/Off (RT format models)
Communication slot 1 slot for Network-M2, Network-MS, ModBus-MS or Relay-MS cards.
Operating conditions, standards and approvals
Operating temperature 0 to 40°C continuous
Typical noise level <46dB <46dB <48 dB <50 dB
Safety IEC/EN 62040-1, UL 1778 & CSA 22.2 (5 & 6kVA RT only)
EMC, performance IEC/EN 62040 -2 , IEC/EN 62040-3
Approvals CE, CB report (TUV), UL (5 & 6kVA RT only)
Dimensions H x W x D/Weight
UPS Tower: 575x244x542mm/65.5kg, RT: 440(19’’)x130(3U)x685mm/48kg 440(19’’)*260(6U)*700mm/84kg 440(19 ’’)x260(6U)x700 mm/86 kg
EBM Tower: 575x244x542mm/104,9kg, RT: 440(19’’)x130(3U)x645mm/68kg 440(19’’)*130(3U)*680mm/65kg 440(19 ’’)x130(3U)x680 mm/65 kg
Power module – – 440(19 ’’)x130(3U)x700 mm/19 kg 440(19 ’’)x130(3U)x700 mm/21 kg
Customer service and support
Warranty 2 years warranty
* Runtimes are shown at 0.7 power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc
Parts numbers 9SX 5 kVA 9SX 6 kVA 9SX 8 kVA 9SX 11 kVA
UPS (Tower) 9SX5KI 9SX6KI – –
UPS (RT format)* – – 9SX8KI 9SX11KI
UPS (RT with rack kit)* 9SX5KIRT 9SX6KIRT 9SX8KIRT 9SX11KIRT
EBM (Tower) 9SXEBM240T 9SXEBM240T – –
EBM (RT format) – – 9SXEBM240 9SXEBM240
EBM (RT with rack kit) 9SXEBM180RT 9SXEBM180RT – –
Power Module – – 9SX8KIPM 9SX11KIPM
HotSwap Maintenance ByPass MBP6KI MBP6KI MBP11KI MBP11KI
Supercharger with Rack Kit – – SC240RT SC240RT
1.8m Battery Connection Cable Tower: EBMCBL240T, RT: EBMCBL180 Tower: EBMCBL240T, RT: EBMCBL180 EBMCBL240 EBMCBL240
Rack Kit – – 9RK 9

Reviews

There are no reviews yet.

Be the first to review “Eaton 9SX UPS 8 KVA RT6U”

Your email address will not be published. Required fields are marked *

Open chat
Need help?
Hello!
Can we help find what you need faster?